OPC Servers for the power industry
Cybectec OPC Servers for the power industry are specially designed
with the protocols and functions required to help you integrate control
centers and substation devices in a modern automation system.
Cybectec's OPC Servers are based on the field-proven SMP Substation Gateway protocol technology used by a growing
number of utilities worldwide to implement mission-critical substation
automation systems.
Click to download OPC Servers
Cybectec OPC Server Features
- Support OPC Data Access 2.05a
- Available for IEC 60870-5-101, IEC 60870-5-104 and DNP3 protocols
- Easy to set up and configure
- Complete set of diagnostic tools
- Unlimited number of tags
- Millisecond time tagging
- Select, Execute and Cancel control functions
- High-performance multi-thread design
- Comprehensive online documentation
- One year of free upgrades
About OPC Servers
OPC is an open standard that permits a consistent
method of accessing field data from plant floor devices. Interoperability is
assured through the creation and maintenance of open standards
specifications. Data Access is one of these standards. To learn more about
OPC and the Data Access standard, please visit the OPC Foundation website at
http://opcfoundation.org/.
|
|
The IEC 60870-5-101 and IEC 60870-5-104 protocols are
recommended by IEEE for communication among master stations, RTUs (Remote
Terminal Units) and IEDs (Intelligent Electronic Devices).
The IEC 60870-5-101 protocol applies to serial communication
links, while IEC 60870-5-104 applies to TCP/IP communication links.
Both OPC servers are available in master or slave configurations. A master
OPC server polls slave devices while a slave OPC server responds to requests
sent by a master device.
|
IEC 60870-5-101 / 104 OPC Server Features
- Available in master or slave configurations
- Support multiple TCP/IP connections (IEC 60870-5-104)
- Support multiple serial connections at bit rates up to 115200 bps (IEC 60870-5-101)
- Automatic device time synchronization with server clock
- Fully configurable polling cycle
- Queuing function prevents loss of events caused by the OPC Data Access
refresh rate limitations
- Time-tagged commands (IEC 60870-5-104)
- Import and export configuration text files
- Support OPC Alarm & Events 1.10
The DNP3 (DNP 3.0) protocol is recommended by IEEE for communication
among master stations, RTUs (Remote Terminal Units) and IEDs (Intelligent
Electronic Devices). DNP3 (Distributed Network Protocol) is widely used by
the electrical utility industry in North America.
Cybectec's DNP3 OPC Server applies to both serial and TCP/IP
communication links. The DNP3 OPC Server is available in a master
configuration.
DNP3 OPC Server Features
- Supports multiple serial connections at bit rates up to 115200 bps
- Supports RS-485 multi-drop devices
- Supports multiple TCP/IP connections
- Completely configurable polling cycle
- Automatic device time synchronization with server clock
- Select, Execute and Cancel control functions
- Latched or pulsed output
- Queuing function prevents loss of events caused by the OPC Data Access
refresh rate limitations
- Import and export configuration text files
- Runs as a Windows service
OPC Characteristics
- Windows 95, 98, 2000, NT and XP
- Supports OPC Data Access 1.0a and 2.05a
- Supports OPC remote tag browsers
NEW! SMP OPC Server:
Reduce the number of installed OPC Servers
With Cybectec's SMP OPC
Server and the SMP Gateway, you only need to install one OPC server on the
server side. Since the SMP Gateway can handle the vast majority of
proprietary and standard protocols in the industrial field, it takes charge
of all the protocol conversion and data concentration. The OPC Server simply
acts as a data relay to other OPC-compatible applications.
More >>>
Contact
sales@cybectec.com for more information and to obtain a copy of the
technical overview document.
SMP Gateway OPC Server Features
- OPC Data Access 3.0, 2.05a and 1.0a support
- Dynamic configuration of the item address space
- Simple and fast configuration
- Transition queuing for binary inputs/outputs
- Direct execution control functions
|